Datasheet Number: D211
|
| Colour Range | Available in a wide range of colours. |
| Dry Film Thickness | Nominal 225 micrometers, depending on profile. |
| Drying Time | Armawall Primer 2 Hours. Armawall Satin 4 Hours. Note: This may be lengthened in damp, cold or humid conditions. Do not apply at temperatures below 10°C. |
| Odour | Low |
| Profile | Low |
| Spread Rate | 4m2/litre. |
| Water Resistance | Excellent. |
| Weathering Resistance | Excellent. |
| Specifications met | APAS 0117/2 |
| Properties | Water Vapour Permeability: Sd 0.5m (100mm dry film thickness) Carbon Dioxide Permeability:Rb 56.4m (100mm dry film thickness) Chloride Ion Diffusion Coefficient: 3 x 10 -3 Elongation 260%. |
New cement render, masonry and concrete surfaces
New cement render, masonry and concrete surfaces should be allowed to cure for 28 days until the alkalinity is below PH10. Off form concrete should be thoroughly cleaned by acid etching, water or sand blasting to ensure all bond breaker oils are removed. All masonry surfaces should be primed with Armawall Primer (thinned 50-100% with water) prior to the application of Armawall Satin. Remove bondbreaker from tilt slab concrete and seal with Armawall Sealer/ Bonder to ensure adhesion of topcoats.
Previously painted surfaces – in sound condition
Previously painted surfaces in sound condition should be scrubbed down with detergent and fresh water, fresh water washed and allowed to dry.
Previously painted enamel surfaces
Previously painted enamel surfaces should be undercoated with Taubmans Tradecoat. Surface irregularities such as blow holes and profile defects may require patching with Armawall Filler or Patch prior to system application.
Armawall Satin can be used in a number of ways: 1. Apply 1 coat by roller over other Armawall textures as a decorative dirt shedding topcoat (4m2/litre). 2. Apply 2 coats over primed concrete with a texture roller for a low profile finish (2m2/litre each coat). 3. Apply 2 coats over primed concrete with a roller or spray to achieve a smooth membrane finish (4m2/litre each coat).
Cleanup
Water, away from drains and watercourses.
Stirring
Stir Armawall Satin prior to use.
Temperature
Avoid application when temperature is below 10°C and above 35°C.